Namespace: decoders

airlock.sdks.honeywell.decoders

Honeywell Barcode Decoders
Source:

Type Definitions

Aztec

Properties:
Name Type Default Description
minimumLength number 1
maximumLength number 3832
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Codabar

Properties:
Name Type Default Description
checkDigitMode object 0
concatEnabled bool false
startStopTransmitEnabled bool false
minimumLength number 2
maximumLength number 60
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

CodablockA

Properties:
Name Type Default Description
minimumLength number 0
maximumLength number 2048
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

CodablockF

Properties:
Name Type Default Description
minimumLength number 0
maximumLength number 2048
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Code11

Properties:
Name Type Default Description
checkDigitMode object 2
minimumLength number 1
maximumLength number 80
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Code39

Properties:
Name Type Default Description
base32Enabled bool false
checkDigitMode object 0
fullAsciiEnabled bool false
startStopTransmitEnabled bool false
minimumLength number 0
maximumLength number 48
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Code93

Properties:
Name Type Default Description
minimumLength number 0
maximumLength number 80
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Code128

Properties:
Name Type Default Description
minimumLength number 0
maximumLength number 80
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Composite

Properties:
Name Type Default Description
minimumLength number 1
maximumLength number 300
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Datamatrix

Properties:
Name Type Default Description
minimumLength number 1
maximumLength number 3116
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Ean8

Properties:
Name Type Default Description
addendaRequired bool false
addendaSeparatorEnabled bool false
checkDigitTransmit bool false
fiveCharAddendaEnabled bool false
twoCharAddendaEnabled bool false
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Ean13

Properties:
Name Type Default Description
addendaRequired bool false
addendaSeparatorEnabled bool false
checkDigitTransmit bool false
fiveCharAddendaEnabled bool false
twoCharAddendaEnabled bool false
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

GS1128

Properties:
Name Type Default Description
minimumLength number 0
maximumLength number 80
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

HaxXin

Properties:
Name Type Default Description
minimumLength number 1
maximumLength number 6000
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Iata25

Properties:
Name Type Default Description
minimumLength number 4
maximumLength number 80
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Interleaved25

Properties:
Name Type Default Description
checkDigitMode object
minimumLength number 2
maximumLength number 80
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Isbt128

Properties:
Name Type Default Description
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Matrix25

Properties:
Name Type Default Description
minimumLength number 4
maximumLength number 80
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Maxicode

Properties:
Name Type Default Description
minimumLength number 1
maximumLength number 150
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

MicroPdf417

Properties:
Name Type Default Description
minimumLength number 1
maximumLength number 2750
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Msi

Properties:
Name Type Default Description
checkDigitMode object 0
minimumLength number 4
maximumLength number 48
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Pdf417

Properties:
Name Type Default Description
minimumLength number 1
maximumLength number 2750
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

PostalChina

Properties:
Name Type Default Description
minimumLength number 4
maximumLength number 80
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

PostalKorean

Properties:
Name Type Default Description
minimumLength number 4
maximumLength number 48
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

QRCode

Properties:
Name Type Default Description
minimumLength number 1
maximumLength number 7089
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Rss

Properties:
Name Type Default Description
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

RssExpanded

Properties:
Name Type Default Description
minimumLength number 1
maximumLength number 80
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

RssLimited

Properties:
Name Type Default Description
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Standard25

Properties:
Name Type Default Description
minimumLength number 4
maximumLength number 48
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Telepen

Properties:
Name Type Default Description
oldStyleEnabled bool false
minimumLength number 1
maximumLength number 60
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Tlc39

Properties:
Name Type Default Description
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Trioptic

Properties:
Name Type Default Description
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Upca

Properties:
Name Type Default Description
addendaRequired bool false
addendaSeparatorEnabled bool false
checkDigitTransmitEnabled bool false
combineCouponCodeModeEnabled bool false
couponCodeModeEnabled bool false
fiveCharAddendaEnabled bool false
numberSystemTransmitEnabled bool true
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source:

Upce

Properties:
Name Type Default Description
addendaRequired bool false
addendaSeparatorEnabled bool false
checkDigitTransmitEnabled bool false
e1Enabled bool false
expandToUpcA bool false
fiveCharAddendaEnabled bool false
numberSystemTransmitEnabled bool true
twoCharAddendaEnabled bool false
enabled boolean true Gets or sets a value indicating if the decoder is used to interpret barcodes.
Source: